TCR-SLI GEN2 Quickstart
Thank you for choosing a Parametric Analytics product. You have chosen a quality product Made in Switzerland. Each counter is handmade and individually tested.
This Quick Start Guide explains all the steps necessary to get the device up and running. Click on the images to enlarge them.
Further information like LoRaWAN® integration, payload decoding can be found in the TCR Users Manual.
1. UNBOXING
Check content
Open the box and check the contents.
Optional parts when ordered together with the counter.
Charge battery first
As long as the device is not yet installed outdoors, it should be charged with the included USB adapter. This keeps the battery fresh and prevents damage from deep discharge.
Push the plug from SOL_EXT4 cable into the socket of the M12SOL adapter. Then connect the plug of the USB Adapter with the other end.
Connect USB Adapter with an USB port of your PC or (better) a USB hub.
2. PLANNING
To achieve the most accurate measurement possible, planning the installation is essential.
Horizontal or Top Down?
The devices can be operated both directly next to the road or elevated and looking down from above. We recommend using a laser measuring tool or a laser pointer to align the device correctly.
Important Rules
The device works best when the following rules are observed.
LTR vs RTL
The TCR traffic counters distinguish between 2 directions.
- RTL = objects which come from the right and disappear to the left. The left LED will pulse once in this case.
- LTR = objects which come from the left and disappear to the right. The right LED will pulse once in this case.
Measure distance to lanes
In order for the device to determine the velocities, the distance to the object must be known. The distance can be determined with a tape measure or a laser distance meter. Measurements are taken from the middle of a track to the front of the device.
- RTLDist = Distance in cm to the RTL movement line.
- LTRDist = Distance in cm to the LTR movement line.
3. CONFIGURATION
Connect USB cable
Open the service lid and connect a USB-to-Micro-USB cable Connect the other end to a Windows PCs USB-Port. The RTL LED should start to blink.
Configure using PPX
While the device is connected to the PC open ppx.parametric.ch to access the online configuration tool. Follow the instructions on the screen to establish a connection.
Set Distance to Lanes
Once connected open Radar-Settings and find Left To Right Lane Distance and Right To Left Lane Distance
- Enter LTRDist value you measured in #measure-distance-to-lanes) into the field LTRDist
- Enter RTLDist value you measure in #measure-distance-to-lanes) into the field RTLDist
- Press Save
4. INSTALLATION
M12 Solar Adapter Plug
The M12 connectors have a coding notch (A Coding).
Important:
Check the pins before plugging in
Rotate the plug so that the notch matches the pin in the socket
Carefully insert the plug by hand
Gently tighten knurled screw by hand
Plug the MP12SOL adapter onto the M12 socket and tighten the ring by hand.
Mount MT80
Carefully tighten the MT80-15 holder with the supplied screws. Use a 25 HEX screw driver for that.
Warning: Using longer screws could crack the enclosure.
Extend the Solar Cable
Use the SOL-EXT4 extension cable if you mount the solar panel more then 20cm away from the counter.
Installing the Counter
If you mount the counter to a pole or mast use pipe clamps or metal straps of suitable length to secure MT80-15 bracket.
Installing the Solarpanel
Mount the solar panel in a place where it gets enough sunlight during the day. Use pipe clamps or metal straps of suitable length to secure the bracket to the pole.
Adjust to pole diameter
Adjust SOLMT bracket to match your pole diameter.
Adjust azimuth
You can change the angle of the solar panel to harvest more solar energy. Or you can fix the panel in a vertical position so that no snow or dust can remain on it.
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Parametric GmbH, its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Parametric”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product.
Parametric makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Parametric disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Parametric's knowledge of typical requirements that are often placed on Paramtric products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer's technical experts. Product specifications do not expand or otherwise modify Paramtric's terms and conditions of purchase, including but not limited to the warranty expressed therein.
Hyperlinks may direct users to third-party websites. These links are provided as a convenience and for informational purposes only. Inclusion of these hyperlinks does not constitute an endorsement or an approval by Parametric of any of the products, services or opinions of the corporation, organization or individual associated with the third-party website. Parametric disclaims any and all liability and bears no responsibility for the accuracy, legality or content of the third-party website or for that of subsequent links.
Except as expressly indicated in writing, Parametric products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Parametric product could result in personal injury or death. Customers using or selling Parametric products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Parametric personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Parametric. Product names and markings noted herein may be trademarks of their respective owners